Building upon a solid foundation, we raise the performance bar
even higher with the JetStor SAS Model 616F. Featuring dual-redundant
active/active array controllers, this 16 bay RAID array
delivers reliable data protection combined with the high performance
of 4Gbit Fiber Channel host interfaces and quad 3Gbit SAS disk
channel expanders to support mission critical business applications.
Engineered to meet stringent demands for continuous availability,
JetStor SAS 616F RAID array spotlights a brand-new 128-bit AMCC
RISC processor for blazingly fast parity calculation and I/O
operations, completely cableless SAS backplane-based design
with SES capabilities, and storage capacities reaching 16TB
in one small 3U enclosure. Low service and integration
costs are assured by the JetStor's cableless design, two redundant
hot-swappable power supplies with two independent power inputs,
turbo cooling fans, and dual embedded RAID controllers. Three
year warranty comes standard with every array and covers all
components.
JetStor SAS 616F RAID addresses many challenges present in
datacenters and delivers unparalleled storage flexibility,
higher levels of data availability, management and configuration
simplicity, all while securing maximum investment protection
to support future growth.

|

|

|



|

|

|

SAS drive capacities of 73GB (15,000 rpm), 146GB (15,000 rpm),
and 300GB (15,000 rpm) are available. SATA drive capacities
of 750GB (7,200 rpm) and 1TB (7,200 rpm) are available.
Per enclosure maximum capacity 4800GB when using 300GB SAS
drives.
Per enclosure maximum capacity of 16TB when using 1TB SATA
drives.
Scaleable to 64 Terabytes with three additional expansion
chassis.

|

|

|



|

|

|

RAID Architecture
|

|
128-bit RISC 533MHz AMCC 440SPe
CPU
Up to 1200 Mbytes/sec internal bandwidth
PCIe bus architecture
|

|
Host Bus Interface
|

|
Two, 4Gbit Fiber Channel, optical
LC connectors per controller
Dual loop, point-to-point, and fabric supported
|

|
Disk Bus Interface
|

|
Sixteen dual-ported 3Gbit SAS
|

|
Command Queuing
|

|
512 commands (host FC channels)
|

|
Cache
|

|
Up to 2GB per controller
667MHz DDR II ECC cache memory
|

|
Operating Systems Supported
|

|
Windows Server 2003, Sun/Solaris,
Linux, and others to be announced
|

|
Temperature
|

|
50°F to 104°F operating, -40°F
to +140°F non-operating 10°C to 40°C operating, -40°C
to +60°C non-operating
|

|
Relative Humidity
|

|
10% to 85% non-condensing (operating),
5% to 90% non-condensing (non-operating)
|

|
Certifications
|

|
FCC, CE, TUV, and UL/CSA
|

|
Size/Weight
|

|
19" wide, 20.5" deep, 5.25" (3U)
high; 52 lb. / 24 kg. (without disk drives)
|

|
I/O Connectors (per controller)
|

|
Two optical LC fiber channel;
RS-232 serial terminal port, UPS port
RJ45 Ethernet management port
SAS Expansion port
|

|
Power Required
|

|
110 or 220 VAC, ±20% @ 10 amps
/ 5 amps peak; 47 to 63 Hz. autosensing
Two independent power inputs
|

|

|

|
|

|


|

|
 |
 |
 |
 |
| |
Online
Configuration |
 |
| i |
Pricing
& More... |
| |
| Choose
required capacity & RAID level to get
an instant online price/config...
|
|
|
|
 |
 |
| |
 
|

|

|

High Performance File Server
High Volume Mail Server
Exchange Server
Database Server

|

|

|
  
|

|

|

Exclusive RAID Manager configuration, monitoring, and notification
software provides instant access to the status of the RAID Array
and allows for 24x7 RAID monitoring and notification. Dual
FC host connection can support multiple hosts simultaneously.
Perfect for clustered environments, e.g. MSCS - Microsoft
Cluster Server.
Up to sixteen low-profile SAS or SATA disk drives per enclosure.
Automatic drive failure detection with pre-emptive drive
cloning on demand.
RAID controller provides RAID 0, 10, 1, and 5, Global Hot
Spare Disk, Auto Rebuild, and up to 2GB of mirrored data cache.
Optional 72 hours battery backup for mirrored data cache.
Intelligent SAS backplane design allows "hot swapping" of
disk canisters, power supplies, and fans for increased reliability,
lower cost, and ease of maintenance.
Lightweight aluminum chassis design.
Environmental Monitor module allows observation of critical
operating parameters via the front LCD panel.
In-band SES (SCSI Enclosure Services) monitoring via SAS.
MPIO-based active/active dual redundant controller operation.

|

|

|
  
|

|

|
 JetStor SAS 616F
JetStor SATA 516F

|

|

|
|

|